1500°C Crucible Furnace
Product Details
Our 1500°C Crucible Furnace is designed for easy maintenance and convenient operation. The efficient design allows for dependability and durability. This unit automatically sets the PID values for your thermal process.
Request A Quote
Click here to request a quote for one of Lindberg/MPH's standard or custom heat treat and melting furnaces.
Request a QuoteKey Specifications
Model | Top Vestibule ID inches (cm) | Heated Depth inches (cm) | Wattage | Overall Dim. inches (cm) | Use w/ Control Type | Shipping Weight lbs. |
---|---|---|---|---|---|---|
56623 | 5 (12.7) | 8 (20.3) | 6,140 | 30x33x33 (76.2×83.8×83.8) | 58125 | 650 |
56953 | 9 (22.9) | 12 (30) | 6,800 | 33x35x35 (83.8x 88.9×88.9) | 58125 | 700 |
56253 | 12 (30) | 12 (30) | 12,000 | 34x38x38 (86.4×96.5×96.5) | 58155 | 710 |
56283 | 12 (30) | 18 (45.7) | 14,800 | 38x39x39 (96.5x99x99) | 58155 | 800 |
1500°C Crucible Controller Models | Preset TC Input | Preset Control Range | Maximum Current | Voltage | Hertz | Overall Size HxWxD in inches (cm) | Shipping Weight lbs. |
---|---|---|---|---|---|---|---|
58125 | Type R | 1-1500°C | 60 Amp | 208/240 | 50/60 | 10 x 14 x 19 (25.4 x 35.6 x 48.3) | 30 |
58155 | Type R | 1-1500°C | 90 Amps | 208/240 | 50/60 | 17 x 17 x 21 (43.2 x 43.2 x 53.3) | 50 |
Specifications and Product Information are subject to change without notice.
Benefits
- Automatically sets the PID values for your thermal process
- Compatible with SPECVIEW® data acquisition software
- Convenient operation
- Easy maintenance
- Efficient design allows for dependability and durability
Features
- High-temperature grade insulation
- Platinum/ Platinum 13% rhodium thermocouple lead wire and plug
- Tight-fitting insulating vestibule plug
- Vertical, single-ended silicon carbide heating elements
- Control Console:
- Programmable temperature controller with solid-state power module, On/Off switch and thermocouple
- PID control algorithm. Offers 10 programs, 24 segments each
- Multiple outputs, along with panel mounted Ethernet communications port
- I-Tools communication cable
- Separate adjustable digital over-temperature control (factory installed)
- Protects furnace and load in the event of primary control circuit failure
- Overrides the main controller, and shuts off power to elements if a high limit is reached
- Manual reset required for safety
- Operates via magnetic contacts through signal from independent thermocouple
Options
- Combustible gas safety system
- Inert atmosphere retorts (this limits the maximum temperature capacity to 1050°C)
- Nanodac paperless chart recorder