1500°C Crucible Furnace

1500°C Crucible Furnace

Product Details

Our 1500°C Crucible Furnace is designed for easy maintenance and convenient operation. The efficient design allows for dependability and durability. This unit automatically sets the PID values for your thermal process.

Request A Quote

Click here to request a quote for one of Lindberg/MPH's standard or custom heat treat and melting furnaces.

Request a Quote

Key Specifications

ModelTop Vestibule ID
inches (cm)
Heated Depth
inches (cm)
WattageOverall Dim.
inches (cm)
Use w/
Control Type
Shipping Weight lbs.
569539 (22.9)12 (30)6,80033x35x35
(83.8x 88.9×88.9)
58125700
5628312 (30)18 (45.7)14,80038x39x39
(96.5x99x99)
58155800
1500°C Crucible
Controller Models
Preset TC InputPreset Control
Range
Maximum
Current
VoltageHertzOverall Size
HxWxD in inches (cm)
Shipping Weight lbs.
58125Type R1-1500°C60 Amp208/24050/6010 x 14 x 19
(25.4 x 35.6 x 48.3)
30
58155Type R1-1500°C90 Amps208/24050/6017 x 17 x 21
(43.2 x 43.2 x 53.3)
50
Specifications and product information are subject to change without notice. Additional models, sizes, and configurations may be available. If you do not see the specific product you are looking for, please contact us.

Benefits

  • Automatically sets the PID values for your thermal process
  • Compatible with SPECVIEW® data acquisition software
  • Convenient operation
  • Easy maintenance
  • Efficient design allows for dependability and durability

Features

  • High-temperature grade insulation
  • Platinum/ Platinum 13% rhodium thermocouple lead wire and plug
  • Tight-fitting insulating vestibule plug
  • Vertical, single-ended silicon carbide heating elements
  • Control Console:
    • Programmable temperature controller with solid-state power module, On/Off switch and thermocouple
    • PID control algorithm. Offers 10 programs, 24 segments each
    • Multiple outputs, along with panel mounted Ethernet communications port
    • I-Tools communication cable
    • Separate adjustable digital over-temperature control (factory installed)
      • Protects furnace and load in the event of primary control circuit failure
      • Overrides the main controller, and shuts off power to elements if a high limit is reached
      • Manual reset required for safety
      • Operates via magnetic contacts through signal from independent thermocouple

Options

  • Combustible gas safety system
  • Nanodac paperless chart recorder