Specifications
Tenney Altitude / Vacuum Chambers <<Go
Back
|
|
|
|
Tenneystrat Test Chamber
Overall dimensions in inches/centimeters
| Model |
T5ST |
10ST |
15ST |
27ST |
36ST |
48ST |
64ST |
| System Horsepower Size |
4 |
6 |
15 |
6 |
15 |
6 |
15 |
20 |
6 |
15 |
20 |
15 |
20 |
30 |
15 |
20 |
30 |
| Workspace |
W |
21/53 |
24/61 |
24/61 |
36/91 |
36/91 |
48/122 |
48/122 |
| D |
21/53 |
24/61 |
36/91 |
36/91 |
48/122 |
36/91 |
48/122 |
| H |
48/122 |
30/76 |
30/76 |
36/91 |
36/91 |
48/122 |
48/122 |
| Exterior |
W |
25/51 |
51/130 |
52/130 |
63/160 |
63/160 |
77/196 |
77/196 |
| D |
63/152 |
99/203 |
111/236 |
111/241 |
123/272 |
123-1/2
/ 281 |
135-1/2
/ 312 |
| H |
78/183 |
84/210 |
84/213 |
90/229 |
90/229 |
91/231 |
91/231 |
| Utilities, etc |
| Heater
Capacity |
2 |
4 |
6 |
8 |
8 |
16 |
16 |
| Humdifier |
Watts |
1 |
2 |
3 |
| GPH |
1.05 |
1.0 |
1.5 |
| AMPS @
230V, 3 |
33(1) |
48 |
81 |
52 |
85 |
63 |
96 |
130 |
63 |
96 |
130 |
120 |
149 |
183 |
120 |
149 |
183 |
| AMPS,
Fuse |
45 |
70 |
110 |
70 |
120 |
80 |
125 |
175 |
80 |
125 |
175 |
150 |
200 |
250 |
150 |
200 |
250 |
| Cooling
Water, 20C GPM |
- |
3 |
6 |
3 |
6 |
3 |
6 |
9 |
3 |
6 |
9 |
6 |
9 |
12 |
6 |
9 |
12 |
| Unit Weight |
LBS/KG |
1300/590 |
3150/1429 |
4850/2200 |
3150/1429 |
6550/2971 |
11,500/5216 |
13,050/5920 |
Notes:
- Humidity capability: 20% to 98% RH in the temperature range
of +20C to +85C as limited by a 3 dewpoint.
- Humidity not achieved simultaneously with altitude.
- Add suffix "R" to model number for humidity.
- Vacuum performance: All chambers achieve altitude up to
100,000 feet (8.2 mm Hg) in 35 minutes. Optional features extend altitude capabilities to
150,000 feet (1 mm Hg) and 200,000 feet (0.17 mm Hg).
- Combined temperature and altitude to 60,000 feet maximum.
- Test data based on a 24C ambient, sea level, 60 Hz.
Performance slightly reduced on 50 Hz. Power requirements based on standard vacuum pump.
|
|