Specifications
Tenney Environmental Chambers          <<Go Back
 
 

ETCU Series

Single Stage Refrigeration
Temperature Range: -35 C to 200 C

Model ETCU-04 ETCU-09 ETCU-16 ETCU-30 ETCU-64
Interior Volume 4 cu. ft.
127 liters
9 cu. ft.
256 liters
16 cu. ft.
460 liters
30 cu. ft.
850 liters
64 cu. ft.
1,812 liters
Interior Dimensions
WxDxH - inches (mm)
24 x 18 x 18
(610 x 457 x 457)
24 x 25 x 26
(610 x 635 x 660)
36 x 26 x 30
(914 x 660 x 762)
40 x 36 x 36
(1,016 x 914 x 914)
48 x 48 x 48
(1,219 x 1,219 x 1,219)
Exterior Dimensions
WxDxH - inches (mm)
34 x 67 x 75
(864 x 1,702 x 1,905)
34 x 73 x 79
(864 x 1,854 x 2,007)
46 x 75 x 83
(1,169 x 1,905 x 2,108)
50 x 88 x 89
(1,271 x 2,235 x 2,261)
58 x 100 x 101
(1,474 x 2,540 x 2,565)
Horsepower 2.5 5.0 2.5 5.0 10.0 2.5 5.0 10.0 2.5 5.0 10.0 15.0 2.5 5.0 10.0 15.0
Compressor Type Scroll Scroll Scroll Scroll Scroll
Heating
Elements
(kW)
230/460V 6 6 6 12 12 6 12 12 6 12 12 24 6 12 12 24
208V 4.5 4.5 4.5 9 9 4.5 9 9 4.5 9 9 18 4.5 9 9 18
Cooling Rate (min)
190C to -35C 28 15 38 20 10 75 25 15 95 46 22 16 157 75 37 26
71C to -35C 23 12 32 17 8 68 23 14 86 41 20 14 142 67 34 23
85C to -20C 15 8 18 10 8 25 14 11 32 23 16 9 53 38 27 14
Heating Rate (min)
-35C to 190C 23 23 37 15 15 34 19 19 53 27 27 18 100 48 48 25
-20C to 85C 9 9 17 6 6 16 9 9 26 13 13 9 47 23 23 12
-35C to 71C 10 10 16 6 6 14 9 9 26 13 13 9 47 23 23 12
Water Cooled · · · · · · · · · · · · · · · ·
Air Cooled · * · * * · · * · · * * · · * *
208/230V-1 · N/A · N/A N/A · N/A N/A · N/A N/A N/A · N/A N/A N/A
208/230V-3 · · · · N/A · · N/A · · N/A N/A · · N/A N/A
460V-3 · · · · · · · · · · · · · · · ·
Air Delivery System
(Blower Hp)
Hp Hp (2) Hp (2) Hp (2) Hp
Airflow (CFM) 750 750 1600 1600 1600
Temp Uniformity
(Std Dev/9 Point)
+/-0.5C/+/-1C +/-0.5C/+/-1C +/-0.5C/+/-1C +/-0.5C/+/-1C +/-0.5C/+/-1C
Temp Control +/-0.3C +/-0.3C +/-0.3C +/-0.3C +/-0.3C
  • Performance is based upon an empty chamber operating at 24C (75F) ambient air and may vary slightly at other ambient temperatures. Voltages below those listed may affect performance. All performance data is for 240 or 480V / 60Hz operation.
  • LN2 is available as an option on all systems. When LN2 is provided, the heater Kw is automatically upgraded to the maximum for that chamber size. Consult factory for current draw of any LN2 equipped chambers.
  • Airflow circulation is based on blower wheel performance curves. Actual circulation rate will vary depending on the cooling option selected.
  • Temperature uniformity Standard deviation from the mean, measured at –25C and 100C. 9 Point: Uniformity measured in accordance with ASTM E145 section 4 at temperatures of –25C and 100C.
  • Test chamber performance may be affected by the addition of certain optional accessories.
  • 17% Performance reduction will be observed on 50Hz Model
  • It is Tenney ’s policy to constantly improve quality, features and performance. Tenney reserves the right to change specifications without notice.

* Contact Tenney for details and availability


Cascade Refrigeration Specifications
Temperature Range: -73 C to 200 C

Model ETCU-04 ETCU-09 ETCU-16 ETCU-30 ETCU-64
Interior Volume 4 cu. ft.
127 liters
9 cu. ft.
256 liters
16 cu. ft.
460 liters
30 cu. ft.
850 liters
64 cu. ft.
1,812 liters
Interior Dimensions
WxDxH - inches (mm)
24 x 18 x 18
(610 x 457 x 457)
24 x 25 x 26
(610 x 635 x 660)
36 x 26 x 30
(914 x 660 x 762)
40 x 36 x 36
(1,016 x 914 x 914)
48 x 48 x 48
(1,219 x 1,219 x 1,219)
Exterior Dimensions
WxDxH - inches (mm)
34 x 67 x 75
(864 x 1,702 x 1,905)
34 x 73 x 79
(864 x 1,854 x 2,007)
46 x 75 x 83
(1,169 x 1,905 x 2,108)
50 x 88 x 89
(1,271 x 2,235 x 2,261)
58 x 100 x 101
(1,474 x 2,540 x 2,565)
Horsepower 2.5 x 2.5 5 x 5  2.5 x 2.5 5 x 5 10 x 10 2.5 x 2.5 5 x 5 10 x 10 2.5 x 2.5 5 x 5 10 x 10 15 x 15 2.5 x 2.5 5 x 5 10 x 10 15 x 15
Compressor Type Scroll Scroll Scroll Scroll Scroll
Heating Elements (Kw) 230/460 6 6 6 12 12 6 12 12 6 12 12 24 6 12 12 24
208V 4.5 4.5 4.5 9 9 4.5 9 9 4.5 9 9 18 4.5 9 9 18
Cooling Rate (min)
190C to -65C 44 20 49 34 14 78 36 19 155 76 38 28 256 125 60 45
71C to -65C 33 14 36 26 11 40 28 15 119 59 26 17 197 97 44 33
85C to -40C 24 10 27 18 8 32 20 12 95 42 21 12 157 69 36 24
Heating Rate (min)
-65C to 190C 24 24 35 16 16 32 22 22 60 30 30 20 110 53 53 27
-65C to 71C 10 10 17 8 8 14 11 11 27 13 13 10 45 23 23 13
-40C to 85C 11 11 16 8 8 12 10 10 27 13 13 11 45 23 23 14
Water cooled · · · · · · · · · · · · · · · ·
Air cooled · * · * * · · * · · * * · · * *
208/230V-1 · N/A · N/A N/A · N/A N/A · N/A N/A N/A · N/A N/A N/A
208/230V-3 · · · · N/A · · N/A · · N/A N/A · · N/A N/A
460V-3 · · · · · · · · · · · · · · · ·
Air Delivery System (Blower HP) Hp Hp (2) Hp (2) Hp (2) Hp
Airflow (CFM) 750 750 1600 1600 1600
Temp Uniformity (Std Dev/9 Point) +/-0.5C/+/-1C +/-0.5C/+/-1C +/-0.5C/+/-1C +/-0.5C/+/-1C +/-0.5C/+/-1C
Temp Control +/-0.3C +/-0.3C +/-0.3C +/-0.3C +/-0.3C
  •  Performance is based upon an empty chamber operating at 24C (75F) ambient air and may vary slightly at other ambient temperatures. Voltages below those listed may affect performance. All performance data is for 240 or 480V / 60Hz operation.
  •  LN2 is available as an option on all systems. When LN2 is provided, the heater KW is automatically upgraded to the maximum for that chamber size. Consult factory for current draw of any LN2 equipped chambers.
  • Airflow circulation is based on blower wheel performance curves. Actual circulation rate will vary depending on the cooling option selected.
  • Temperature uniformity Standard deviation from the mean, measured at –25C and 100C. 9 Point: Uniformity measured in accordance with ASTM E145 section 4 at temperatures of –25C and 100C.
  • Test chamber performance may be affected by the addition of certain optional accessories.

* Contact Tenney for details and availability

 

 