Lindberg Heat Treat Furnaces Heat Treat Furnaces and Non Ferrous Melting Equipment

Lindberg Heat Treat Furnaces
 

Vertical Pit Vacuum Furnace Specifications

Go Back
 

Typical Dimensions

Model Pit Width Pit Depth Furnace Height Installation Area Length Installation Area Width Lift Clearance Maximum water flow GPM
22-GR-1520-24TF -- -- 6'-9" 9' 7'-6" 1'-8" 15
22-GR-2436-24TF 8' 3'-6" 12'-8" 17' 12' 1'-8" 40
22-GR-3830-17/24TF 10' 3' 12'-1" 18' 14' 1'-8" 50
22-GR-3848-17TF 10' 4'-6" 13'-7" 18' 14" 1'-8" 60
22-GR-3872-24TF 10' 6'-6" 15'-7" 18' 14' 1'-8" 80
22-GR-38156-24TF 10' 17'-6" 27'-6" 18' 14' 3' 120
22-GR-4248-24TF 10' 4"-6" 11'-10" 14'-6" 14' 3' 100
22-GR-4296-24TF 10'-6" 8'-5" 16'-3" 16'-5" 14' 3' 120
22-GR-4490-24TF 10'-6" 7-2" 17' 18' 12' 3' 120

1750 °F Model

Model (1) Work Space (2) Input kW Fan HP Max. Load Weight (lbs.) Approx. Wt (lbs.)
Dia. (in.) Depth (in.
22-GR-3830-17TF 38 30 75 15 2,000 14,000
22-GR-3848-17TF 38 48 120 15 3,000 15,000
22-GR-4296-17TF 42 96 300 30 4,200 20,000
Note (1) - All covers are air lift.
Note (2) - Load space, actual work chamber is larger.
Note (3) - Heavier loading available, contact factory.
Model Mech Pump Blower Max (1) Water GPM Backfill Gas CF Surge Tank
HP CFM HP CFM CF Weight
22-GR-3830-17TF 10 300 7.5 1,300 200 140 19 375
22-GR-3848-17TF 10 300 10 1,600 275 175 34 640
22-GR-4296-17TF 10 300 10 1,600 470 275 57 725
Note (1) - Flow is for very rapid cooling conditions, not typical. Usual water flow is about 50% of that shown.
All models ultimate vacuum 1 x 10-2 Torr.
All models 2.5 psig maximum cooling backfill pressure.

2400 °F Model

Model (1) Work Space (2) Input kW Fan HP Max. Load Weight (lbs.) Approx. Wt (lbs.)
Dia. (in.) Depth (in.
22-GR-1520-24TF 15 20 45 2 250 8,500
22-GR-2436-24TF 24 36 90 15 1,000 12,000
22-GR-3830-24TF 38 30 150 15 2,000 14,000
22-GR-3872-24TF 38 72 240 25 3,600 16,750
22-GR-38156-24TF 38 156 360 25 4,500 21,400
22-GR-4248-24TF 42 48 250 30 2,000 15,000
22-GR-4490-24TF 44 90 300 20 4,500 18,000
Note (1) - All covers are air lift.
Note (2) - Load space, actual work chamber is larger.
Note (3) - Heavier loading available, contact factory.
Model Mech Pump Blower Max (1) Water GPM Backfill Gas CF Surge Tank
HP CFM HP CFM CF Weight
22-GR-1520-24TF 5 80 1 100 35 23 19 375
22-GR-2436-24TF 7.5 150 2 300 100 100 19 375
22-GR-3830-24TF 10 300 7.5 1,600 200 140 19 375
22-GR-3872-24TF 10 300 10 1,600 375 225 34 640
22-GR-38156-24TF 10 300 10 1,600 800 500 93 1300
22-GR-4248-24TF 10 300 10 1,600 275 175 34 640
22-GR-4490-24TF 10 300 10 1,600 470 275 57 725
Note (1) - Flow is for very rapid cooling conditions, not typical. Usual water flow is about 50% of that shown.
All models ultimate vacuum 1 x 10-2 Torr.