Lindberg/Blue M™ 1500°C Industrial Box Furnace

Lindberg/Blue M™ 1500 Box Furnace

The 1500°C Industrial Box Furnace maintains temperature uniformity, has a rapid response rate and boasts a dense load capability. It’s long element life is essential for energy efficiency and low maintenance to meet today’s workplace requirements.



Benefits

  • Rapid response rate
  • Dense load capability
  • Long element life Energy efficiency
  • Low maintenance required

Features

  • Insulating vestibules and directly hinged, insulated plug doors
  • Internal vent that dissipates the initial heat surge from open door
  • Type "R" thermocouple
  • Silicon carbide heating elements horizontally positioned above and below the heating chamber
  • High-temperature graded insulation
  • Fitted silicon-carbide hearthplate
  • Double shell, heavy duty construction
  • Low temperature outer shell
  • Chamber Sizes:
    • 360 Cu. Inches - 43.84 Cu. Feet
  • Controllers Available:
    • 58125, 58175, 58185
  • Temperature: 1500ºC (2732ºF) Maximum

Options

  • Ethernet communications available
  • Programmable Controller (Option P)
  • Offers the convenient flexibility of ramping to multiple setpoint temperatures and holding for variable time periods at those temperatures
  • Temperature controller provides 16 programmable segments consisting  of ramps or dwells
    • Provides up to four 16-programmable segments or one 64-segment program
    Excess temperature protection (Option B)
  • Provides positive protection of both furnace and load in event of failure in the primary control circuit
    Atmosphere Retorts
  • Available for all 1500°C box furnaces when controlled atmosphere  processing is required.
  • Atmosphere Control Consoles
  • Atmosphere retort limits the maximum temperature capacity to 1050°C in lieu of 1500°C with retort installed
Furnace
Model
Chamber Dimensions
W x H x D in. (cm)
Outer Dimensions
W x H x D in. (cm)
Wattage Shipping Weight (lbs.) Control Console
Model No.
51333 6 x 5 x 12
(15.2 x 12.7 x 30.5)
25 x 26 x 29
(63.5 x 66 x 73.7)
5,900 400 58125
51663 12 x 12 x 14
(30.5 x 30.5 x 35.6)
37 x 36 x 33
(94 x 91.4 x 83.8)
23,000 765 58175
51683 12 x 12 x 24
(30.5 x 30.5 x 61)
38 x 39 x 40
(96.5 x 99.1 x 101.6)
20,800 985 58175
51863 16 x 16 x 24
(40.6 x 40.6 x 61)
41 x 44 x 42
(104.1 x 111.8 x 106.7)
23,400 1,198 58185
Control Console
Model
Preset TC Input Preset Control
Range
Maximum
Current / Zone
Voltage Hertz Overall Size
HxWxD in inches (cm)
Shipping
Weight lbs
58125 Type R 1-1500°C
60 Amps 208/240 50/60 10 x 14 x 19
(25.4 x 35.6 x 48.3)
30
58175 Type R 1-1500°C
120 Amps 208/240 50/60
17 x 17 x 21
(43.2 x 43.2 x 53.3)
55
58185 Type R 1-1500°C 180 Amps 208/240 50/60 17 x 24 x 21
(43.2 x 61 x 53.3)
80